this post was submitted on 25 Aug 2023
16 points (94.4% liked)

Ask Electronics

3332 readers
2 users here now

For questions about component-level electronic circuits, tools and equipment.

Rules

1: Be nice.

2: Be on-topic (eg: Electronic, not electrical).

3: No commercial stuff, buying, selling or valuations.

4: Be safe.


founded 1 year ago
MODERATORS
 

I am powering a 5V microcontroller (arduino clone, atmega328p) using a 9V block and a buck converter. Now I want to let the microcontroller occasionally measure the battery voltage, so I can get an idea of how full it is.

My first idea was to use a simple voltage divider:

I've chosen the resistor values so that:

  • the voltage at the measure output is < 1.1V, to be able to use the 1.1V internal reference of the atmega's ADC
  • R1 || R2 < 10kΩ, since the atmega datasheet says "The ADC is optimized for analog signals with an output impedance of approximately 10 kΩ or less"

This is great and all, but what bothers me is that this circuit will constantly draw ~100µA from the battery.

So, my next thought was to add a mosfet to the divider, to switch it on only while measuring:

This is obviously bad, because now when the mosfet is off, the ADC input sees the whole battery voltage.

To address that issue, I've added a second mosfet into the measure path:

This works, and it does not draw any current, except while measuring.

However, it's quite a few parts. So I'm curious if anyone has an idea how to do this with just a single mosfet. It seems to me like it should be possible, but I haven't figured out how.

Oh, and if I'm doing something stupid here, please tell me :)

you are viewing a single comment's thread
view the rest of the comments
[–] nilclass@discuss.tchncs.de 3 points 1 year ago (1 children)

You could probably increase the 82K and 10K resistors to be much bigger

That's what I thought initially, but this stackoverflow post dissuaded me. The argument there is that the measurement will be wrong, if the input current is not enough to charge the internal cap within the measurement period. But I've done some testing now, and measurements done with 820k and 100k agree well with what my voltmeter measures, so I'll go with this solution!

a fresh alkaline 9V battery is actually 9.6V or more, not 9V.

Indeed! 9.6V * 10k/92k = 1.04V is still below 1.1V, so I should be fine in this case :)

9V battery voltages droop noticeably when under load because of their high internal resistance. Make sure to measure under the same conditions.

This is a good point!

My firmware will be pretty monotonic though, basically:

  1. wake up
  2. measure battery
  3. measure some other sensors (the actual task of the device)
  4. turn on a transceiver, send all the measurements (including battery voltage)
  5. turn off transceiver & go to sleep

So, the load should be always the same at step (2).

@nilclass

@WaterWaiver

From the stack exchange post: " 10 kΩ or less source resistance is recommended, otherwise the low pass filter effect of the capacitor with the source resistance becomes a major issue, requiring a longer sampling time for conversion and as a result limiting the maximum frequency."

In other words: a higher source impedance (caused by large resistors) is only going to drastically affect the results when you need to take fast repeated measurements (e.g. an AC source)