this post was submitted on 28 Jul 2024
17 points (94.7% liked)
Gardening
3468 readers
5 users here now
Your Ultimate Gardening Guide.
Rules
- Be respectful and inclusive.
- No harassment, hate speech, or trolling.
- Engage in constructive discussions.
- Share relevant content.
- Follow guidelines and moderators' instructions.
- Use appropriate language and tone.
- Report violations.
- Foster a continuous learning environment.
founded 1 year ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
view the rest of the comments
Doesn’t one picture show 195 psi and the other 59? I think your gauge is out, tap pressure shouldn’t be almost 200 psi.
oh don't worry about red needle (it's some kind of inertia guage?), it's pushed by black needle as soon as water starts and can be freely moved by dial on top
@SchmidtGenetics @rando my tap pressure had always been around 195. I now have 2 regulators inside house that I never needed before I got a new hot water heater. Incredible outside pressure, have to be careful with soaker in garden.
Pex is rated at 120 psi at hot water temperatures and only 160 psi at room temperature. So I seriously doubt that.
Rated pressure != burst pressure. I would expect a line rated at 160PSI line pressure to withstand at least 200PSI before bursting.
Water hammer can drastically increase line pressure; a line rated at 160PSI should be able to handle the transient pressure spikes that commonly occur in a 160PSI line.
Deliberately pushing 200PSI into a line rated for 160PSI is certainly not safe or acceptable, but I wouldn't be surprised to see it hold, and I would be surprised to see it fail.